TURNING YOUR RAYBURN ON

Open the burner door ( L.H. lower) to gain access to the burner which should look like this.

The burner will have a control knob like this.

To Light.

1. Turn off the electrical supply to the Rayburn

2. Turn the thermostat knob 'D' to its lowest setting or OFF position

3. Make sure that any external gas cocks are turned ON. Turn ON the service cock 'E' so that the line mark on the cock is in line with the pipe.

4. Turn knob 'B' to the 'Ignition' position and depress fully, at the same time operating the spark generator 'C' until the pilot flame ignites.

5. Keep the control knob 'B' depressed for at least a further 15 seconds before releasing.

6. If the pilot then goes out, wait 3 minutes, before repeating the procedure, but holding the knob in for slightly longer.

7. With the pilot flame established, turn knob 'B' to the 'ON' position. With early models (up to and including 1995) will the main burner will then light. On later models, the electricity should now be switched on and the thermostat knob 'D' turned to the 'LOW' setting, when the main burner will then light.

8. Keep the burner on low for about 5 minutes, after which the thermostat may be turned to the setting required.

9. When the correct oven temperature is reached, or if the electricity is turned off by a timeclock or otherwise, or the thermostat knob is turned to a lower setting, then the main burner will, on early models, go to a low flame idling condition, or, on later models - extinguish completely.

WARNING. If the burner fails to ignite or operate properly; or there is a smell of gas or fumes; or you are unsure if the cooker has been serviced recently, --- DO NOT USE --- Have the appliance checked by a qualified engineer.


TURNING YOUR RAYBURN OFF

If the Rayburn is only to be off for a few days, it is acceptable to leave the pilot alight. In this case, switch OFF the electricity supply to the Rayburn and turn the thermostat knob 'D' to the OFF position.

For longer periods and to turn the pilot off as well,

Open the burner door ( L.H. lower) to gain access to the burner controls.

Turn the control knob 'B' to the GAS OFF position, which will extinguish the pilot flame.